Carl Stuart Limited T/A Lab Unlimited is the authorised representative for the Brookfield Ametek Instrument range in Ireland for both Technical Sales and Service Support. Lab Unlimited engineers have been factory trained and certified by Brookfield Ametek to carry out calibration and repairs of their entire range including Viscometers, Rheometers, Texture Analysers and Powder Flow Testers.
We offer both an Onsite and Back to Base PM, Calibration & Repair service at a time/date that suits your operational needs. We offer a customised service and calibration support to meet your requirements, Frequency of Calibration, Preventive Maintenance, Calibration Standards.
We offer a yearly/bi-annual/quarterly service and calibration or are flexible to your requirements within your industry.
All Brookfield Laboratory Viscometers are accurate within +/- 1.0% of the range in use and have a reproducibility within +/- 0.2% so test results can be duplicated anywhere in the world when the same model instrument is used.
Our Service Team would be happy to provide you with a competitive Quotation based around your requirements. Please call us on 01 4523432 or email service@labunlimited.com
Looking to purchase a new machine, visit our webshop: www.labunlimited.com/Brookfield
Below are some of the more common questions asked about Viscosity and the calibration and maintenance of a Viscosity instrument. If you have a question that's not covered here, please send it to service@labunlimited.com
A: Calibration and Certification is recommended every 12 months to ensure optimum operating conditions however depending on the instrument use and the sample type tested there may be a requirement for an increased frequency. Our trained support team will be able to advise on this.
A: The process of choosing a spindle and speed to suit an unknown sample is one of initial trial and error. The objective is to choose a spindle that will produce a display reading between 10% and 90% torque. If a sample has historically been tested using a specific speed and spindle combination, the user should use that same combination. (insert link to spindle page)
A: Test your Brookfield Viscometer/Rheometer with a Brookfield Viscosity Standard Fluid at 3 different rotational speeds to verify how the instrument responds when sensing low, medium, and high % torques.
Example:
RV Viscometer with RV #3 spindle at 20, 10, and 5 rpm
Brookfield Viscosity Standard Fluid: Nominal value = 5000 cP; Actual value = 4850 cP.
For more on Brookfield Viscosity Standard Fluids, visit our webshop: www.labunlimited.com/689/Brookfield-Viscosity-Standard
A:
A: For most liquids viscosity has an inverse relationship with temperature. As temperature increases, viscosity decreases. For this reason, it is critical to control the temperature of a sample during any viscosity measurement.
A: Please see below table:
**Model | Min. cP(mPa•s) Viscosity Range | Max. cP(mPa•s) Viscosity Range | No. of Speeds | No. of Spindles Supplied | |
---|---|---|---|---|---|
Low Viscosity |
LVT | 1* | 2 M | 8 | 4 |
LVDV-E | 1* | 2 M | 18 | 4 | |
DV1MLV | 1* | 2 M | 18 | 4 | |
DV2TLV | 1* | 6 M | 200 | 4 | |
DV3TLV | 1* | 6 M | 2600 | 4 | |
Medium Viscosity |
RVT | 100 | 8 M | 10 | 6 |
RVDV-E | 100 | 13 M | 18 | 6 | |
DV1MRV | 100 | 13 M | 18 | 6 | |
DV2TRV | 100 | 40 M | 200 | 6 | |
DV3TRV | 100 | 40 M | 2600 | 6 | |
High Viscosity | HAT | 200 | 16 M | 10 | 6 |
HADV-E | 200 | 26 M | 18 | 6 | |
DV1MHA | 200 | 26 M | 18 | 6 | |
DV2THA | 200 | 80 M | 200 | 6 | |
DV3THA | 200 | 80 M | 2600 | 6 | |
HBT | 800 | 64 M | 10 | 6 | |
HBDV-E | 800 | 104 M | 18 | 6 | |
DV1MHB | 800 | 104 M | 18 | 6 | |
DV2THB | 800 | 320 M | 200 | 6 | |
DV3THB | 800 | 320 M | 2600 | 6 | |
**Standard torque range values M = 1 million |